A boiler can look perfectly healthy and still be quietly letting you down. This Vaillant ecoFIT pure in Earlsfield, SW18 was a good example. It was heating the house and making hot water, but the high combustion readings we took on a previous visit meant it needed a proper look, and that is never something we sign off and walk away from.
We recommended a full strip-down boiler service instead of a quick once-over, and the customer agreed. What we found on the second visit was a lot more interesting than a dirty burner.
The Short Version: What We Did
- Full strip-down service on the Vaillant ecoFIT pure to chase down the high combustion readings
- New electrodes and new burner gaskets
- Condensate trap cleaned out
- Faulty pressure sensor replaced
- Leaking rear flue seal and cap found and replaced, which meant taking the boiler off the wall
- Expansion vessel pressurised and gas valve adjusted
- Full 26.9 safety checks carried out at the end
Starting With the Full Strip-Down Service
We stripped the boiler down the way we do on every full service. The electrodes came out and new ones went in, and we replaced the burner gaskets while the burner was out. We also cleaned out the condensate trap, which is a common cause of boilers locking out and well worth doing every time.


A Pressure Sensor That Was Telling Lies
While checking the system pressure we noticed the pressure sensor wasn’t giving a true reading. What the boiler displayed didn’t match the actual pressure in the system. You can see the state of the old sensor below, with residue on the end of it. We replaced it, because a boiler that doesn’t know its own pressure can’t protect itself properly.

The Real Culprit: A Leaking Rear Flue Seal
Here’s what made this job worth writing about. This boiler has a rear flue, and when we checked the flue connection at the back, the seal and cap were leaking combustion products. That is what had been behind the high combustion readings on the first visit.
You can service a boiler as thoroughly as you like, but if the flue seal is letting products escape, the readings will never come right. This is exactly why we don’t just clean a boiler and hope for the best.
Boiler Off the Wall to Replace the Flue Seal
To replace it properly, the boiler had to come off the wall. There’s no other way to get at a rear flue connection. It’s more work than a standard service, but it’s the only way to do the job right.

Here is the old gasket next to the new one. The old one is worn and ragged on the inside edge, so it was never going to seal properly.

With the new seal fitted on the flue turret, we put the boiler back on the wall and reconnected everything.

Expansion Vessel and Gas Valve
With the boiler back on the wall we checked the expansion vessel and pressurised it to the correct pressure, then adjusted the gas valve.

The 26.9 Safety Checks and Combustion Readings
Once everything was back together we ran the 26.9 checks. These are the safety checks you carry out whenever you work on a boiler:
- Flue flow check
- Combustion readings taken with the analyser
- Gas rate check
With the new seal in place, the high combustion readings were dealt with at the source: the boiler was running safely and the readings were where they should be.

Why High Combustion Readings Shouldn’t Be Ignored
If your boiler has been giving high combustion readings, or an engineer has told you to keep an eye on it, don’t leave it. A proper service is the only way to find out what is behind the numbers. In this case it came down to a worn flue seal, but it was letting combustion products out where they shouldn’t be, and that is not something to leave.
Boiler Service Questions We Get Asked
What causes high combustion readings on a boiler?
There are a few possible causes, including a dirty burner or heat exchanger, worn electrodes, an incorrect gas valve setting, or a problem with the flue such as a leaking seal. The only way to know is to strip the boiler down and check each one, which is what a full service does.
Is a leaking flue seal dangerous?
It can be. A flue seal that leaks lets combustion products escape, and those can include carbon monoxide. If you suspect a problem, get it checked by a Gas Safe registered engineer, and make sure you have a working carbon monoxide alarm.
How often should a boiler be serviced?
Once a year. An annual service keeps the boiler safe and efficient, and it’s how problems like this one get picked up before they turn into something worse.
Does a boiler have to come off the wall to change a rear flue seal?
On a rear flue like this one, yes. You need the boiler off the wall to get at the connection and fit the new seal properly.
Boiler Service in Earlsfield, SW18
If you’re in Earlsfield, SW18 or the surrounding areas and your boiler is giving high combustion readings, making noises or just hasn’t been looked at in a while, get in touch with MAK Plumbing and Heating. We’re Gas Safe registered and we’ll find out what’s really going on.
